Sample Report

See how Chiller Trend turns routine chiller readings into clearer comparisons, stronger reports, and findings teams can defend.

A report is only as strong as the method behind the reading.

What changes

From stored readings to operating evidence.

Chiller Trend does not just make a prettier log sheet. It standardizes the reading, checks the data, calculates missing context, and helps explain what the comparison means.

Standard Log View

Paper logs record the readings, but they do not automatically make the performance comparison obvious.

Standard Log View

Stacked standard chiller log sheets from 3737 Buffalo Speedway

The readings are recorded, but the performance gap may not be obvious from the log alone.

Chiller Trend Comparison

The gap becomes visible when the readings are standardized, calculated, and compared.

What the Calculations Reveal

Chiller Trend marked-up comparison showing CH-1 operating 45 percent higher kW per ton than CH-2
Chiller Trend chart example showing CH-1 and CH-2 performance trends

What this shows

The paper logs captured the readings, but the performance difference became clear after the values were standardized and compared. This is a finding that deserves review, not a final diagnosis by itself.

Chiller Trend does the work the paper log cannot: it turns raw readings into calculated performance data and exposes the gap between the two chillers.

What Chiller Trend Adds to a Normal Log

The same field readings become calculated, compared, and easier to explain.

Structured Reading

Temperatures, pressures, amps, volts, setpoints, and notes are captured in one consistent workflow.

#

Calculated Outputs

Tons, flow, approach, lift, and kW/ton are calculated from the logged data.

Performance Comparison

Readings can be compared against design, baseline, and similar machines.

Clearer Findings

The result is a cleaner log, clearer findings, and a customer-facing explanation the team can stand behind.

A standard log records the reading. Chiller Trend adds the calculation layer behind it.

Diagnostic Findings

When the data supports it, Chiller Trend helps organize the reading into clear follow-up items without overclaiming certainty.

Watch

Efficiency Difference From Similar Machine

CH-1 shows higher kW/ton than CH-2 under comparable logged conditions. Review supporting factors before assigning cause, including load, lift, flow, compressor speed, vane position, and control behavior.

Normal

Flow Compared Against Design

Evaporator and condenser flow percentages appear near design in this example. That helps narrow the review toward other operating factors instead of assuming a flow issue from the efficiency number alone.

Not Verified

Root Cause

The higher kW/ton is a finding, not a final diagnosis. Chiller Trend helps make the gap visible so a qualified technician can review the machine and supporting conditions.

Executive Summary

Technical readings are converted into a clearer explanation for owners, managers, and internal teams.

Example Summary

Two similar chillers were reviewed under comparable logged conditions. At first glance, the standard logs looked similar. After the readings were standardized and calculated, CH-1 showed a materially higher kW/ton than CH-2.

This does not prove the root cause by itself. It does show that the performance difference is large enough to deserve review. The next step is to verify the supporting conditions and determine whether the difference is caused by machine operation, controls, flow behavior, sensor inputs, or another site-specific factor.

The value of the report is not that it guesses the answer. The value is that it makes the gap visible, explains why it matters, and gives the team a clearer place to start.

Chiller Trend reports are built to show what changed, what the data supports, and what still needs to be verified.

Turn Routine Chiller Readings Into Better Operating Evidence

Start with one site, one chiller, or one comparison. See how a standardized workflow changes what the data can support.